Hi~welcome to shenzhen xinmu display technology co., ltd.!
2025-07-21 177
Let me remind you first. If the power supply of the receiving card is connected by randomly, you can experience what "heartbeat acceleration" is in minutes:
Lessons of blood and tears: Last month, I helped my friend repair the transparent screen in the bar and found that the receiving card was actually connected behind the dimmer. The voltage is insufficient during the day and the display is incomplete, and the current is overloaded at night and the wiring method is simply a textbook-level negative case!
Remember this rumor:"Check the voltage of the marking and identification line, and ensure safety in independent circuits"
| Scene Type | Power supply specifications | Protection requirements | Alternative plan |
|---|---|---|---|
| Outdoor advertising screen | Waterproof 12V/10A | IP65-level junction box | Automatic switching of dual power supplies |
| Stage floor tiles screen | Shockproof 5V/20A | Spring terminals prevent falling off | Each card is open independently |
| Sports fence screen | Wide pressure 48V/5A | Lightning protection module | Three-phase balanced power supply |
| Transparent window screen | Ultra-thin 5V/8A | Anti-electromagnetic shielding | Redundant parallel design |
Key reminder: Encounter withIntelligent brightness adjustmentRemember to install the voltage regulator for the receiving card! At a brand press conference last year, when the screen automatically illuminates with the ambient light, the current fluctuation directly kills the receiver card.
Don’t rush to turn on the computer after connecting the cable. These three steps can avoid 90% of accidents:
Real cases: The most outrageous way to connect the network cable to power it - 8 network cables are connected in parallel as power cables, and the transmission data and power supply interfere with each other, and the snowflakes on the screen are so big that they can play a ghost movie!
After working on the display for so many years, I foundWhether the power supply is connected directly determines the life of the screen. A truly reliable manufacturer considers power management from the design stage: for example Common Yin drive technologySave 30% of power, or install the receiving cardOvervoltage and overcurrent protection chip. Some high-end models can even monitor the voltage fluctuations of each receiving card in real time through the mobile APP, which is really worry-free!
Next time I encounter a power wiring problem, remember these three truths:"Dedicated line test three times, lightning protection, stupidity protection, and hand care". After all, whether the screen is lit or not depends on whether the power is given enough stability!
for more product information and pricing, please contact us .