Hi~welcome to shenzhen xinmu display technology co., ltd.!
2025-08-04 157
"After pressing more than twenty buttons, the restart button cannot be found! " Last month, when I helped my friend debug the large screen in the conference room, I saw him sweating with my own eyes. Industry data shows that 38% of LED screen repairs actually require restarting to solve, but many people cannot find the switch position at all. Today we will break through this seemingly simple question.
Large box screen:
▪ The lower right corner of the front: Metal button with lightning logo (backlit model will shine in dark environments)
▪ Side maintenance port: You need to use a Phillips screwdriver to open the cover (a warning sticker for "Not professionals to operate")
▪ Hide design: Press and hold the "Mode Switch Key" for 3 seconds to trigger a soft restart (note that the indicator light turns red and then turns green)
Rental screen/floor tiles screen:
▸ Inside the groove on the back of the box (anti-touch design)
▸ The magnetic protective cover needs to be unlocked by sliding to the right
▸ Special models need to be rotated 90 degrees with supporting keys
Transparent screen/special screen:
→ Red emergency button on the side of the control box (diameter is usually 5mm)
→ Distributed power systems may be equipped with multiple switches (distance not exceeding 1.5 meters)
→ Key points: Forced restart of this type of screen may lose brightness parameters. It is recommended to soft shut down first
× Directly unplug the power cord
▪ Sudden power outage will cause damage to the storage data of the control card (the maintenance fee starts at 300 yuan)
▪ Correct posture: Turn off the screen power first, wait until the cooling fan stops and then turn off the power
× Continuous fast button press
▸ An employee in a shopping mall pressed 15 times and caused the button module to burn (replacement fee is 480 yuan)
▸ The system response takes 3-5 seconds, please patiently check the indicator light status
× Self-disassembly control box
→ Possible triggering of tamper sensor (reset of special equipment required)
→ Breakage of screw hole seal directly affects quality assurance
Outdoor screen failed on rainy days:
The show crashed midway:
→ Enable backup signal channel (pre-wiring can save 3,000 yuan in losses)
→ Quickly unplug HDMI cable to trigger heat reset (success rate 87%)
→ Ultimate solution: block the faulty area and enable the emergency subtitle system
Multi-screen linkage abnormality:
Industry cold knowledge: Professional-grade LED screens actually have two sets of restart systems - the physical switches visible to users are just appearances, and the real core reset key is hidden on the back of the control card chip and needs to be triggered with a hex wrench. But this is a manufacturer's maintenance confidentiality. Private operation will cause the equipment to be locked. Last time I met a master and took three hours to unlock it successfully. This money is really worth saving.
(This article’s operating guide is applicable to equipment that has passed IP54 or above protection certification, and the data comes from the 2024 Electronic Engineering Association Technical White Paper)
for more product information and pricing, please contact us .